Fast shipping
Pay easily via Klarna or Afterpay
30 day money back guarantee
SPRSUN Greenergy R290 Heat Pump | ERP A+++ | 40 dB(A) | −25 °C | Up to 75 °C
ERP A+++ (35 °C) R290 (propane) Super quiet from 40 dB(A)

SPRSUN Greenergy Series – R290 DC Inverter Air-to-Water Heat Pumps

The Greenergy series naturally combines R290 with a modulating DC inverter for powerful, quiet and economical heating and cooling. Reliable operation down to −25 °C and outgoing water up to 75 °C makes this series ideal for renovation and new construction.

75 °C
Max. outgoing water
−25 °C
Winter operation
40 dB(A)
Sound pressure from
WiFi
Touchscreen & App
SPRSUN Greenergy R290 heat pump leaflet
Image for illustrative purposes only. Models and dimensions may vary.

Key Benefits

Maximum efficiency

DC inverter compressors deliver high efficiency and stable comfort with low consumption — ErP A+++ (35 °C) .

Silent operation

Optimization of air flows and housing for sound pressure from 40 dB(A) .

High water temperatures

Up to 75°C outgoing water — perfect for renovations with existing radiators.

All-climate performance

Reliable down to −25 °C with smart defrost cycles.

Smart control

Touchscreen controller, WiFi app, schedules and SG-Ready .

Service & installation

Built-in pump (model-dependent), clear menus, maintenance-friendly design.

Technology & sustainability

R290 is a natural refrigerant with low GWP. Combined with a modulating DC inverter, this ensures high COP/EER values, stable power, and a smaller CO₂ footprint.

  • DC inverter compressor – on-demand speed for efficiency and comfort.
  • Electronic expansion valve – precise superheat control.
  • Optimized heat exchangers – high transfer, low pressure drop.
  • Intelligent defrosting – less downtime and ice build-up.
  • ErP classification – A+++ (35 °C) / A++ (55 °C) for the entire series.

Models & specifications

Power supplies: CGK020/030/040/050V4P-B – 220–240V 50Hz 1-phase • CGK-030/040/050V4P-B – 380–420V 50Hz 3-phase .

Heating – A7/W35 (outgoing water 35 °C)

Model Max. Heating Capacity (kW) COP (W/W) Heating Capacity Min./Max (kW) Power Input Min./Max (W) COP Min./Max (W/W)
CGK020V4P-B 6.5 4.4 2.20 / 6.50 441 / 1477 4.4 / 4.99
CGK030V4P-B 9.1 4.2 3.15 / 9.10 626 / 2167 4.2 / 5.03
CGK040V4P-B 12 3.9 4.35 / 12.00 885 / 3073 3.90 / 4.92
CGK050V4P-B 15.2 3.95 5.60 / 15.00 1125 / 3800 3.95 / 4.98
CGK-030V4P-B 9.1 4.2 3.15 / 9.10 626 / 2167 4.2 / 5.03
CGK-040V4P-B 12 3.9 4.35 / 12.00 885 / 3073 3.90 / 4.92
CGK-050V4P-B 15 3.95 5.60 / 15.00 1125 / 3800 3.95 / 4.98

Heating – A7/W45 (outgoing water 45 °C)

Model Max. Heating Capacity (kW) COP (W/W) Heating Capacity Min./Max (kW) Power Input Min./Max (W)
CGK020V4P-B 6.30 3.60 2.01 / 6.30 522 / 1750
CGK030V4P-B 8.60 3.52 2.90 / 8.60 757 / 2443
CGK040V4P-B 11.2 3.28 4.00 / 11.20 1071 / 3415
CGK050V4P-B 14.5 3.23 5.40 / 14.50 1427 / 4489
CGK-030V4P-B 8.60 3.52 2.90 / 8.60 757 / 2443
CGK-040V4P-B 11.2 3.28 4.00 / 11.20 1071 / 3415
CGK-050V4P-B 14.5 3.23 5.40 / 14.50 1427 / 4489

Cooling – A35/W18 (outgoing water 18 °C)

Model Max. Cooling Capacity (kW) HONOR (W/W) Cooling Capacity Min./Max (kW) Power Input Min./Max (W) EER Min./Max (W/W)
CGK020V4P-B 5.70 3.48 1.82 / 5.70 463 / 1638 3.48 / 3.93
CGK030V4P-B 7.04 3.43 2.64 / 7.04 677 / 2052 3.43 / 3.90
CGK040V4P-B 10.0 3.40 3.81 / 10.00 1003 / 2941 3.40 / 3.80
CGK050V4P-B 13.6 3.28 5.20 / 13.60 1402 / 4146 3.28 / 3.71
CGK-030V4P-B 7.04 3.43 2.64 / 7.04 677 / 2052 3.43 / 3.90
CGK-040V4P-B 10.0 3.40 3.81 / 10.00 1003 / 2941 3.40 / 3.80
CGK-050V4P-B 13.6 3.28 5.20 / 13.60 1402 / 4146 3.28 / 3.71

Cooling – A35/W7 (outgoing water 7 °C)

Model Max. Cooling Capacity (kW) HONOR (W/W) Cooling Capacity Min./Max (kW) Power Input Min./Max (W) EER Min./Max (W/W) Max Power (kW) Max Current (A) Max Water Pump Head (m) Sound Pressure dB(A) Sound Power dB(A)
CGK020V4P-B 4.45 2.87 1.53 / 4.45 443 / 1551 2.87 / 3.45 3 14.35 9 39 53
CGK030V4P-B 5.63 2.66 2.10 / 5.63 612 / 2117 2.66 / 3.43 4 19.14 9 41 55
CGK040V4P-B 7.2 2.62 3.58 / 7.20 1213 / 2748 2.62 / 2.95 5 23.92 9 44 58
CGK050V4P-B 10.2 2.60 4.69 / 10.20 1520 / 3880 2.63 / 3.09 6.3 30.14 12 43 58
CGK-030V4P-B 5.63 2.66 2.10 / 5.63 612 / 2117 2.66 / 3.43 4 8.44 9 40 54
CGK-040V4P-B 7.2 2.62 3.58 / 7.20 1213 / 2748 2.62 / 2.95 5 10.55 9 43 57
CGK-050V4P-B 10.2 2.60 4.69 / 10.20 1520 / 3880 2.63 / 3.09 6.3 13.29 12 46 60

General

Characteristic Value
Refrigerant R290 (propane)
ErP level (35 °C) A+++
ErP level (55 °C) A++
Housing Weather-resistant PP + galvanized sheet steel

Dimensions & weight

Model Net weight (kg) Gross weight (kg) Dimensions (L×D×H, mm) Box dimensions (L x W x H, mm)
CGK020V4P-B 90 102 1053×475×755 1115×505×910
CGK030V4P-B 106 119 1110×475×810 1165×505×960
CGK040V4P-B 120 133 1110×475×960 1165×505×1100
CGK050V4P-B 135 166 1110×475×1355 1165×505×1520
CGK-030V4P-B 106 119 1110×475×810 1165×505×960
CGK-040V4P-B 120 133 1110×475×960 1165×505×1100
CGK-050V4P-B 135 166 1110×475×1355 1165×505×1520

* Actual performance depends on installation, system temperatures, and conditions. Consult the nameplate and official datasheet for final specifications.

Applications

  • Renovation with radiators – high water temperatures up to 75 °C.
  • Low-temperature systems – underfloor heating/climate ceilings with high seasonal efficiency.
  • Hot water – combine with a suitable boiler tank or integrated solution.
  • All-electric or hybrid – as main heating or in conjunction with an existing boiler.

Installation & service

Quick commissioning

Touchscreen wizard and clear hydraulic diagrams. Built-in pump (model-dependent) simplifies installation.

Sound & placement

With sound pressure levels starting at 40 dB(A), facade or garden installation is often possible. Keep in mind the need for free airflow and reflections.

Maintenance

Annual check of cooling circuit, filters and firmware updates via controller/app recommended.

Quotation & advice

Free system check: upload your consumption data, photos of your indoor/outdoor setup, and desired comfort temperatures. We'll size the right model and provide a clear cost-benefit analysis.

Schedule a consultation Download leaflet (PNG)

Frequently Asked Questions

Is R290 safe?
Yes. R290 is a natural refrigerant with a low GWP. The unit is designed with safety systems; installation by certified specialists is mandatory.
Can this heat pump feed my radiators?
Yes. Up to 75°C outgoing water, suitable for renovations with existing radiators (check output/dimensions).
How quiet is 40 dB(A)?
Similar to a quiet library. The arrangement, reflections, and background all influence the experience.
Does the heat pump work in frost?
Yes, designed for operation down to −25°C with intelligent defrost cycles.
Does the heat pump have app control?
Yes. Wi-Fi app for scheduling, monitoring, and control. SG-Ready for integration with smart energy systems.

No specifications available for this product.