Maximum efficiency
DC inverter compressors deliver high efficiency and stable comfort with low consumption — ErP A+++ (35 °C) .
The Greenergy series naturally combines R290 with a modulating DC inverter for powerful, quiet and economical heating and cooling. Reliable operation down to −25 °C and outgoing water up to 75 °C makes this series ideal for renovation and new construction.
DC inverter compressors deliver high efficiency and stable comfort with low consumption — ErP A+++ (35 °C) .
Optimization of air flows and housing for sound pressure from 40 dB(A) .
Up to 75°C outgoing water — perfect for renovations with existing radiators.
Reliable down to −25 °C with smart defrost cycles.
Touchscreen controller, WiFi app, schedules and SG-Ready .
Built-in pump (model-dependent), clear menus, maintenance-friendly design.
R290 is a natural refrigerant with low GWP. Combined with a modulating DC inverter, this ensures high COP/EER values, stable power, and a smaller CO₂ footprint.
Power supplies: CGK020/030/040/050V4P-B – 220–240V 50Hz 1-phase • CGK-030/040/050V4P-B – 380–420V 50Hz 3-phase .
| Model | Max. Heating Capacity (kW) | COP (W/W) | Heating Capacity Min./Max (kW) | Power Input Min./Max (W) | COP Min./Max (W/W) |
|---|---|---|---|---|---|
| CGK020V4P-B | 6.5 | 4.4 | 2.20 / 6.50 | 441 / 1477 | 4.4 / 4.99 |
| CGK030V4P-B | 9.1 | 4.2 | 3.15 / 9.10 | 626 / 2167 | 4.2 / 5.03 |
| CGK040V4P-B | 12 | 3.9 | 4.35 / 12.00 | 885 / 3073 | 3.90 / 4.92 |
| CGK050V4P-B | 15.2 | 3.95 | 5.60 / 15.00 | 1125 / 3800 | 3.95 / 4.98 |
| CGK-030V4P-B | 9.1 | 4.2 | 3.15 / 9.10 | 626 / 2167 | 4.2 / 5.03 |
| CGK-040V4P-B | 12 | 3.9 | 4.35 / 12.00 | 885 / 3073 | 3.90 / 4.92 |
| CGK-050V4P-B | 15 | 3.95 | 5.60 / 15.00 | 1125 / 3800 | 3.95 / 4.98 |
| Model | Max. Heating Capacity (kW) | COP (W/W) | Heating Capacity Min./Max (kW) | Power Input Min./Max (W) |
|---|---|---|---|---|
| CGK020V4P-B | 6.30 | 3.60 | 2.01 / 6.30 | 522 / 1750 |
| CGK030V4P-B | 8.60 | 3.52 | 2.90 / 8.60 | 757 / 2443 |
| CGK040V4P-B | 11.2 | 3.28 | 4.00 / 11.20 | 1071 / 3415 |
| CGK050V4P-B | 14.5 | 3.23 | 5.40 / 14.50 | 1427 / 4489 |
| CGK-030V4P-B | 8.60 | 3.52 | 2.90 / 8.60 | 757 / 2443 |
| CGK-040V4P-B | 11.2 | 3.28 | 4.00 / 11.20 | 1071 / 3415 |
| CGK-050V4P-B | 14.5 | 3.23 | 5.40 / 14.50 | 1427 / 4489 |
| Model | Max. Cooling Capacity (kW) | HONOR (W/W) | Cooling Capacity Min./Max (kW) | Power Input Min./Max (W) | EER Min./Max (W/W) |
|---|---|---|---|---|---|
| CGK020V4P-B | 5.70 | 3.48 | 1.82 / 5.70 | 463 / 1638 | 3.48 / 3.93 |
| CGK030V4P-B | 7.04 | 3.43 | 2.64 / 7.04 | 677 / 2052 | 3.43 / 3.90 |
| CGK040V4P-B | 10.0 | 3.40 | 3.81 / 10.00 | 1003 / 2941 | 3.40 / 3.80 |
| CGK050V4P-B | 13.6 | 3.28 | 5.20 / 13.60 | 1402 / 4146 | 3.28 / 3.71 |
| CGK-030V4P-B | 7.04 | 3.43 | 2.64 / 7.04 | 677 / 2052 | 3.43 / 3.90 |
| CGK-040V4P-B | 10.0 | 3.40 | 3.81 / 10.00 | 1003 / 2941 | 3.40 / 3.80 |
| CGK-050V4P-B | 13.6 | 3.28 | 5.20 / 13.60 | 1402 / 4146 | 3.28 / 3.71 |
| Model | Max. Cooling Capacity (kW) | HONOR (W/W) | Cooling Capacity Min./Max (kW) | Power Input Min./Max (W) | EER Min./Max (W/W) | Max Power (kW) | Max Current (A) | Max Water Pump Head (m) | Sound Pressure dB(A) | Sound Power dB(A) |
|---|---|---|---|---|---|---|---|---|---|---|
| CGK020V4P-B | 4.45 | 2.87 | 1.53 / 4.45 | 443 / 1551 | 2.87 / 3.45 | 3 | 14.35 | 9 | 39 | 53 |
| CGK030V4P-B | 5.63 | 2.66 | 2.10 / 5.63 | 612 / 2117 | 2.66 / 3.43 | 4 | 19.14 | 9 | 41 | 55 |
| CGK040V4P-B | 7.2 | 2.62 | 3.58 / 7.20 | 1213 / 2748 | 2.62 / 2.95 | 5 | 23.92 | 9 | 44 | 58 |
| CGK050V4P-B | 10.2 | 2.60 | 4.69 / 10.20 | 1520 / 3880 | 2.63 / 3.09 | 6.3 | 30.14 | 12 | 43 | 58 |
| CGK-030V4P-B | 5.63 | 2.66 | 2.10 / 5.63 | 612 / 2117 | 2.66 / 3.43 | 4 | 8.44 | 9 | 40 | 54 |
| CGK-040V4P-B | 7.2 | 2.62 | 3.58 / 7.20 | 1213 / 2748 | 2.62 / 2.95 | 5 | 10.55 | 9 | 43 | 57 |
| CGK-050V4P-B | 10.2 | 2.60 | 4.69 / 10.20 | 1520 / 3880 | 2.63 / 3.09 | 6.3 | 13.29 | 12 | 46 | 60 |
| Characteristic | Value |
|---|---|
| Refrigerant | R290 (propane) |
| ErP level (35 °C) | A+++ |
| ErP level (55 °C) | A++ |
| Housing | Weather-resistant PP + galvanized sheet steel |
| Model | Net weight (kg) | Gross weight (kg) | Dimensions (L×D×H, mm) | Box dimensions (L x W x H, mm) |
|---|---|---|---|---|
| CGK020V4P-B | 90 | 102 | 1053×475×755 | 1115×505×910 |
| CGK030V4P-B | 106 | 119 | 1110×475×810 | 1165×505×960 |
| CGK040V4P-B | 120 | 133 | 1110×475×960 | 1165×505×1100 |
| CGK050V4P-B | 135 | 166 | 1110×475×1355 | 1165×505×1520 |
| CGK-030V4P-B | 106 | 119 | 1110×475×810 | 1165×505×960 |
| CGK-040V4P-B | 120 | 133 | 1110×475×960 | 1165×505×1100 |
| CGK-050V4P-B | 135 | 166 | 1110×475×1355 | 1165×505×1520 |
* Actual performance depends on installation, system temperatures, and conditions. Consult the nameplate and official datasheet for final specifications.
Touchscreen wizard and clear hydraulic diagrams. Built-in pump (model-dependent) simplifies installation.
With sound pressure levels starting at 40 dB(A), facade or garden installation is often possible. Keep in mind the need for free airflow and reflections.
Annual check of cooling circuit, filters and firmware updates via controller/app recommended.
Free system check: upload your consumption data, photos of your indoor/outdoor setup, and desired comfort temperatures. We'll size the right model and provide a clear cost-benefit analysis.
|
No specifications available for this product. |